Range TeSys
Range of product TeSys Deca
product or component type Contactor
Device short name LC1D
contactor application Motor control
Motor control
Utilisation category AC-2
AC-4
AC-3
AC-3e
AC-4
poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
[Ie] rated operational current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
[Uc] control circuit voltage 48 V DC
Complementary
Motor power kW 25 kW at 415 V AC 50 Hz (AC-3)
30 kW at 440 V AC 50 Hz (AC-3)
30 kW at 500 V AC 50 Hz (AC-3)
33 kW at 660…690 V AC 50 Hz (AC-3)
15 kW at 220…230 V AC 50 Hz (AC-3)
11 kW at 400 V AC 50 Hz (AC-4)
30 kW at 1000 V AC 50 Hz (AC-3)
22 kW at 380…400 V AC 50 Hz (AC-3e)
25 kW at 415 V AC 50 Hz (AC-3e)
30 kW at 440 V AC 50 Hz (AC-3e)
30 kW at 500 V AC 50 Hz (AC-3e)
33 kW at 660…690 V AC 50 Hz (AC-3e)
15 kW at 220…230 V AC 50 Hz (AC-3e)
30 kW at 1000 V AC 50 Hz (AC-3e)
22 kW at 380…400 V AC 50 Hz (AC-3)
Motor power hp 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
15 hp at 200/208 V AC 60 Hz for 3 phases motors
15 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
40 hp at 575/600 V AC 60 Hz for 3 phases motors
3 hp at 115 V AC 60 Hz for 1 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 80 A (at 60 °C) for power circuit
10 A (at 60 °C) for control circuit
Irms rated making capacity 140 A AC for control circuit conforming to IEC 60947-5-1
900 A at 440 V for power circuit conforming to IEC 60947
250 A DC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 100 A gG at <= 690 V coordination type 1 for power circuit
100 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1
10 A gG for control circuit conforming to IEC 60947-5-1
Power dissipation per pole 9.6 W AC-1
3.7 W AC-3e
3.7 W AC-3
[Ui] rated insulation voltage Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified conforming to IEC 60947-1
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V CSA certified conforming to IEC 60947-1
Control circuit: 600 V CSA certified
Overvoltage category III
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Mechanical durability 10000000 cycles
Control circuit type DC standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
0.75…1.25 Uc (-40…60 °C):operational DC
0.1…0.3 Uc (-40…70 °C):drop-out DC
Inrush power in VA 160 VA cos phi 0.75 (at 20 °C)
Inrush power in W 19 W (at 20 °C)
Hold-in power consumption in VA 15 VA 50 Hz cos phi 0.3 (at 20 °C)
Hold-in power consumption in W 7.4 W at 20 °C
Rated operational power in W 12 W at 48 V DC-13 – electrical durability: 10000000 cycles – for control circuit
38 W at 48 V DC-13 – electrical durability: 3000000 cycles – for control circuit
Operating time 12…26 ms closing
50 ms closing
20 ms opening
Time constant 34 ms
Maximum operating rate 3600 cyc/h 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw terminals 1 2.5…25 mm² – cable stiffness: rigid
Power circuit: screw terminals 2 2.5…16 mm² – cable stiffness: rigid without cable end
Power circuit: screw terminals 1 2.5…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw terminals 2 2.5…16 mm² – cable stiffness: flexible without cable end
Power circuit: screw terminals 1 2.5…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: rigid
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver Philips No 2
Power circuit: 5 N.m – on screw terminal – with screwdriver flat Ø 6 to Ø 8 mm
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver pozidriv No 2
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver flat Ø 6 mm
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Type mirror contact 1 NC conforming to IEC 60947-4-1
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on energisation between NC and NO contacts
1.5 ms on de-energisation between NC and NO contacts
mounting support Rail
Plate
Environment
Standards UL 508
IEC 60947-5-1
EN 60947-4-1
EN 60947-5-1
CSA C22.2 No 14
IEC 60947-4-1
Product certifications CCC
BV
CSA
GOST
UL
DNV
GL
LROS (Lloyds register of shipping)
UKCA
CSA
IP degree of protection IP2X conforming to VDE 0106
IP2X conforming to IEC 60529
Climatic withstand Conforming to IACS E10 exposure to damp heat
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor closed (15 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor opened (10 Gn for 11 ms)
Height 127 mm
Width 85 mm
Depth 176 mm
net weight 2.185 kg

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “کنتاکتور سری LC1D50E7 اشنایدر”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “کنتاکتور سری LC1D50E7 اشنایدر”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *