Range | TeSys |
---|---|
Range of Product | TeSys Deca |
Product or Component Type | Contactor |
Device short name | LC1D |
contactor application | Motor control Resistive load |
Utilisation category | AC-3 AC-3e AC-4 AC-1 |
poles description | 3P |
[Ue] rated operational voltage | Power circuit <= 300 V DC 25…400 Hz Power circuit <= 690 V AC |
[Ie] rated operational current | 125 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 80 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit |
[Uc] control circuit voltage | 48 V AC 50/60 Hz |
Motor power kW | 22 kW at 220…230 V AC 50/60 Hz (AC-3) 37 kW at 380…400 V AC 50/60 Hz (AC-3) 45 kW at 415…440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660…690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 22 kW at 220…230 V AC 50/60 Hz (AC-3e) 37 kW at 380…400 V AC 50/60 Hz (AC-3e) 45 kW at 415…440 V AC 50/60 Hz (AC-3e) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 660…690 V AC 50/60 Hz (AC-3e) |
---|---|
Maximum Horse Power Rating | 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors 30 hp at 230/240 V AC 50/60 Hz for 3 phase motors 60 hp at 460/480 V AC 50/60 Hz for 3 phase motors 60 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
Compatibility code | LC1D |
Pole contact composition | 3 NO |
Protective cover | With |
[Ith] conventional free air thermal current | 10 A (at 140 °F (60 °C)) for signalling circuit 125 A (at 140 °F (60 °C)) for power circuit |
Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947 |
Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 640 A 104 °F (40 °C) – 10 s for power circuit 990 A 104 °F (40 °C) – 1 s for power circuit 135 A 104 °F (40 °C) – 10 min for power circuit 320 A 104 °F (40 °C) – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit |
Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit |
Average impedance | 0.8 mOhm – Ith 125 A 50 Hz for power circuit |
Power dissipation per pole | 5.1 W AC-3 12.5 W AC-1 5.1 W AC-3e |
[Ui] rated insulation voltage | Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 4 Mcycles |
Electrical durability | 0.8 Mcycles 125 A AC-1 <= 440 V 1.5 Mcycles 80 A AC-3 <= 440 V 1.5 Mcycles 80 A AC-3e <= 440 V |
Control circuit type | AC 50/60 Hz standard |
Coil technology | Without built-in suppressor module |
Control circuit voltage limits | 0.85…1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz 0.3…0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8…1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz 1…1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz |
Inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)) 245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) |
Hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) 26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) |
Heat dissipation | 6…10 W at 50/60 Hz |
Operating time | 20…35 ms closing 6…20 ms opening |
Maximum operating rate | 3600 cyc/h 140 °F (60 °C) |
Connections – terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible without cable end Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: flexible without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible with cable end Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) – cable stiffness: flexible with cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: solid without cable end Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: solid without cable end |
Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2 |
Auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Signalling circuit frequency | 25…400 Hz |
Minimum switching voltage | 17 V for signalling circuit |
Minimum switching current | 5 mA for signalling circuit |
Insulation resistance | > 10 MOhm for signalling circuit |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Mounting Support | Plate Rail |
Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
---|---|
Product Certifications | CSA BV UL GOST RINA CCC GL LROS (Lloyds register of shipping) DNV |
IP degree of protection | IP20 front face IEC 60529 |
Protective treatment | THIEC 60068-2-30 |
Climatic withstand | IACS E10 exposure to damp heat |
Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating |
Operating altitude | 0…9842.52 ft (0…3000 m) |
Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Vibrations contactor open 2 Gn, 5…300 Hz) Shocks contactor open 8 Gn for 11 ms) Vibrations contactor closed 3 Gn, 5…300 Hz) Shocks contactor closed 10 Gn for 11 ms) |
Height | 5.0000000000 in (127 mm) |
Width | 3.3 in (85 mm) |
Depth | 5.1 in (130 mm) |
Net Weight | 3.51 lb(US) (1.59 kg) |
Category | US10I1222359 |
---|---|
Discount Schedule | 0I12 |
GTIN | 3389110440522 |
Returnability | No |
Country of origin | FR |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 6.299 in (16.000 cm) |
Package 1 Width | 5.315 in (13.500 cm) |
Package 1 Length | 3.740 in (9.500 cm) |
Package 1 Weight | 3.426 lb(US) (1.554 kg) |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 5 |
Package 2 Height | 5.9 in (15 cm) |
Package 2 Width | 11.8 in (30 cm) |
Package 2 Length | 15.7 in (40 cm) |
Package 2 Weight | 17.824 lb(US) (8.085 kg) |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 80 |
Package 3 Height | 29.528 in (75.000 cm) |
Package 3 Width | 23.622 in (60.000 cm) |
Package 3 Length | 31.496 in (80.000 cm) |
Package 3 Weight | 293.612 lb(US) (133.180 kg) |
دیدگاهها
هیچ دیدگاهی برای این محصول نوشته نشده است.